This is important that you make which tank of tank & as per which STD your tank had been designed. For example for the LPG & LNG tank that designed As per BS7777 the maximum distortion shall not exceed 75 mm over a distance less than 3 m.
-----Original Message-----
From:
materials-welding@googlegroups.com [mailto:
materials-welding@googlegroups.com] On Behalf Of puneet takiar
Sent: Saturday, July 18, 2009 3:53 PM
To:
materials-welding@googlegroups.comSubject: [MW:2705] Re: Tank bottom
What is to be stored in the tak.
Regards,
Puneet
--- On Tue, 9/6/09, cuyanausul <
albanesmolina@gmail.com> wrote:
> From: cuyanausul <
albanesmolina@gmail.com>
> Subject: [MW:2375] Tank bottom
> To: "Materials & Welding" <
materials-welding@googlegroups.com>
> Date: Tuesday, 9 June, 2009, 3:16 PM
>
> Hello friends
> Api 650 does not specify flatness for tanks, does any one
> know the
> tolerance for inspection and the reference?
> Thanks from a new guy
> Luis
>
> >
>
Yahoo! recommends that you upgrade to the new and safer Internet Explorer 8.
http://downloads.yahoo.com/in/internetexplorer/
¡Obtén la mejor experiencia en la web!
Descarga gratis el nuevo Internet Explorer 8.br> http://downloads.yahoo.com/ieak8/?l=mx --~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---
S355 J2 WP is a weathering structural steel It has better atmospheric corrosion resistance. Use E 8018 - W1/W2 Electrodes This is regular...
No comments:
Post a Comment