I dont know about ANSI B31.1,3 and 4 but as per asme div-1 impact is
not required below 6mm thickness and material P1 up to operating
tempreture -29 degree celcius.
Israr Ahmed
+966530417332
On May 5, 2:59 am, "G.Alagarasan" <galagara...@rediffmail.com> wrote:
> Gents,
>
> Is impact testing required for below material as per ANSI 31.1,31.3,31.4 or any
>
> 1) MSS-SP75-WPHY 65 ( Weld o let) - P1 Gr 2 Material
>
> 2) SA 106 Gr B - P1 Gr 2 Material
>
> Thickness is 2.55mm,5.5mm and 13.5mm
>
> MDMT 0 Deg C
>
> Regards,
> Alagu
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---