Friday, June 19, 2009

[MW:2484] Re: Pl.Help.

Hi Prashant,
 
It seems to be serious mishap at the outset, but if the customer is ok with it, then why should your employer have any issues?
 
If you have any criteria or past experience where you had succesfully used the 10% principle that you can demonstrate to your firm, then I guess you should be ok.
 
I will check further and see if I can get any more information.
 
Thanks
 
Johnson

 
On Wed, Jun 17, 2009 at 6:25 PM, Johnson Madukayil <jmadukayil@gmail.com> wrote:
Hi Prashant,

What do you mean by 10% inspection of seat? Dimensional or visual on hydrotest?

Regards

Johnson

On Wed, Jun 17, 2009 at 1:01 AM, Muni Andy <cmkfc07@gmail.com> wrote:
There is no standard for quantity to be tested for seat test in valves.I agree with Abhijit.
Muni

On Thu, May 28, 2009 at 5:11 PM, prashant pansare <prashantpan_99@yahoo.co.in> wrote:
Abhijit ,
Thanks for u r responce,it gives me lots of moral support & if u find any supporting stds.pl. mail me.
Thanks & Regards,
Prashant 

--- On Thu, 28/5/09, abbey kangale <abhianu12@yahoo.com> wrote:

From: abbey kangale <abhianu12@yahoo.com>
Subject: [MW:2269] Re: Pl.Help. Date: Thursday, 28 May, 2009, 3:48 PM


Prashant
 
I am sorry to say ;their is no such ref standards available in Market which specify Quantum of Inspection Levels
 
At this stage you can issue Inspection reports for all valves mentioneing subject to Acceptance of selected Inspection Levels from your End User/Engineering Consultancey
 
You can issue Inspection report with all your observation and your Inspection Level assumptions but mention clearlycceptance by Client due to unavailbility of QAP/Inspection levels
 
I know this is regularly happens in India with TPI companies and they have to take thier own judgement for their Inspection and isuue Inspection reports with conditional approval.and for that your management has to agree for same .
 
Abhijit  
--- On Thu, 5/28/09, prashant pansare <prashantpan_99@yahoo.co.in> wrote:

From: prashant pansare <prashantpan_99@yahoo.co.in>
Subject: [MW:2267] Pl.Help.
To: materials-welding@googlegroups.com
Date: Thursday, May 28, 2009, 1:11 PM

Dear all,
I' ve inspected ball & NRV ( API 6D)  valves for xyz company.QAP was not available & client also not provided extent of check,but i inspected Hydro test 100% for body & 10% foe seat & released all the valves after satisfactory results.
My firm wants clarification for Why i not done 100% testing for seat also?
I' ve been warned,badly as i' ve carried out inspection without QAP & taken my own decision.
Is there any specs. or std. to rsolve this matter? & if available pl.forward me,so that i can
responce immediately to avoid further action.
Pl. help.
Regards to all ...PRASHANT    


Explore and discover exciting holidays and getaways with Yahoo! India Travel Click here!


Explore and discover exciting holidays and getaways with Yahoo! India Travel
Click here!








--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...