Dear Sir,
For the %of DFT, Please refer SSPC PA 2(Measurement of dry coating
thickness with magnetic gauges) 5.2.1 &5.2.2. In that 80% is the
minimum acceptable area Otherwise it is a non confirmity area.

Regards

Hareesh K V

--
----------------------
Hareesh K V
+91-9447625021

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...