Hi,
Please refer ASME Sec I Non Mandatory Appendix - B Clause B-8
Thanks
Parminder Singh
On Tue, May 23, 2023 at 8:27 AM Sintha Aidroos <iti.sintha@gmail.com> wrote:
Dear experts,Please advise about weld metal deposit composition for base metal cuni 90/10 (UNS C 70600) and filler wire CuNi70/30 (UNS C 71500) combination of this material.We checked PMI at weld joint area but composition is not matching with ASME sec II part C .Can you give guidance for any PMI acceptance criteria?Here I attached PMI report for your review.As per ASME sec II filler metal nickel percentage is 29-32 % and copper remaining.--