Monday, March 2, 2020

[MW:30567] Patch Plate Thickness - API 650 Tank

Dear Experts,

Construction Code: API 653
Annular PlateThickness: 13.5mm
Bottom plate thickness:8.0mm
       We are in a position to weld "Patch Plate" on the Annular ring plates.All the repairs are not in the critical zone (3"inch as per API 653). As per API 653 the patch plate thickness within the critical zone is  1/4" maximum. I could not get any reference for the patch plate thickness beyond the critical zone and within the annular ring plate.

Please kindly give your inputs with code reference.

With Regards,
N.S


--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAMaJw0%2Bfd%3Dc0uZ540d15RP80%2Bu3fRDDmiY5Vg9U3gY8e8zY7jA%40mail.gmail.com.

No comments:

Re: [MW:35241] Overlay welding defects

Dear Sir, The below is another type of defect,Mostly these two type of defects we faced. Regards, R.Gowtham. On Wed, Sep 11, 2024 at 1:42 PM...