I think it may be lack of root fusion could you send me welding procedure for further details. And I can help you
On 31 May 2019 18:31, "Raju Kandula" <rgkandula@gmail.com> wrote:
-- --Dear Experts,Our project (dosing tank) requires welding of SS316/316L plates of 5mm and 6mm Thickness, while welding of 6mm thickness with back weld, after welding on side-1 and back grinding from other end, we are observing porosity in the centre line with intermittent space during first and second phase. (attached LPT photo for reference)Kindly request, to advice your guidance for rectification.RegardsRaju Kandula
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com .
Visit this group at https://groups.google.com/group/materials-welding .
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/ .CALwNT%2B_L0fTF7to9_ 9H97mQpGNZiY9yo7jbZEExcW4% 2BexCFEwg%40mail.gmail.com
For more options, visit https://groups.google.com/d/optout .
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CABjM7-skorT0Qid_xbzA5GBLswkXCnKdpBZ59FjMckHPWaTrNA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment