Saturday, June 29, 2019

Re: [MW:29766] A335 P11 can be used instead of P22

Hi, 

If header pipe is P5A why it is connected with P4 CAP (Tie-in point)? in which P5A weldolet to be fused with P4 CAP? is that your query? 

Is this pre approved design or shortage of material? so you just inserting one what you have?

write a TQ to ''the company'' take approval with disimilar WPS.

I hope there shall not be an issue if you are proposing with your adjustment in case, but designers approval is final.

Yours
MOHAMED MUNEEB MAHABOOB
+91-786-700-444-6      TRZ - INDIA
''do that quality job - which doesn't promise your tomorrow''

Date: 2019-06-27 17:03
Subject: [MW:29753] A335 P11 can be used instead of P22
Dear all,

We have a situation that we need to weld cap (material P11) to weldolet with P22 material. Size 2" NPS. Line temp is 560C and pressure 48bar. The rating of the main header is 1500# P22 mtl. Can we weld to the following conditions P11 mtl cap to weldolet P22 mtl.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAN4%2Bm0wXZEi-VoDnnHJRypawcopE%3DSoK2E0va9iJd3C1gTPJAQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...