Hello,
You have to use E101T1-GM rode, with preheating 180 degree and cover welding with glass wool for 2 hrs or more immediate after welding
Best Regards
Vimal Mistry I Tower SCM-QA
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Somnath Ashtakar
Sent: Wednesday, June 5, 2019 11:29 PM
To: materials-welding@googlegroups.com
Subject: [MW:29681] Welding EN19 to IS 2062
Hi experts,
I am doing welding of EN19 round bar
( dia 80mm ) to IS 2062 E250 BR (25mm thk) plate using E71T-1 electrode
( preheat 150deg & then slow cooling),but getting discontinuities after welding which seems like crack.
Can someone please suggest me right electrode and procedure..
Thanks in advance.
Attached photos for reference.
Regards,
Somnath
9096297210
--