Tuesday, November 1, 2016

[MW:25639] Re: Base metal qualification range of unlisted material as per AWS D1.1

Thanks a lot for the response sir, That was the exact doubt i was having , as  S355 is un listed in AWSD1.1  ,  also The only diffrence between S355J2 and S355JR is the impact test requirement . other properties are same .  

On Monday, 31 October 2016 15:08:49 UTC+4, shaik amjad wrote:
If a wps is qualified in base metal S355J2 will it be qulified for S355JR Code AWS. I have WPS qualified with base metal S355J2  but now due to stock availability only S 355JR is available can i use same WPS for this one also . as only the grade is changing  

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/71747f1d-8be0-4279-b4c8-beda2ef7cd74%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone