Wednesday, October 5, 2016

[MW:25486] Requirement For Shoe Support Pad

Gentlemen s ,

I have 2" to 10" P1 material pipe for Thermic Fluid of design temperature is 250 degree cel. Drawing shows trunnion and shoe supports directly fully welded on the pipes of thickness range 2 to 10 mm . Pls suggest whether its acceptable or need to have a reinforcing pads which is not welded to pipe will be acceptable. 



Thanks in advance

Pratish

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/f8ebb28b-de9b-4bd2-b909-adecf8cdd972%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...