Sunday, September 18, 2016

[MW:25417] WPS for API 5lX70

Dear Mr. Rafiqat,

As per API 1104
5.4.2 changes required for requalification.
Base material
Change in base material constitutes an essential variable. When welding of two separate material groups, the procedure for higher strength group shall be used. There are following material group we need to consider during procedure qualification accordingly.
1. SMYS less than or equal to API 5L X42
2. SMYS greater than API 5L X42 but less than API 5L X65
3. SMYS greater than or equal to API 5L X65, each grade shall receive the separate qualification.

Also you can't change filler metal group as per table 1.

So you can't use API 5L X60 PQR for making WPS of higher grade material.

Regards,
Pravin Nimbalkar,
Welding engineer,
BILFAL heavy industry, KSA.
+966577620240

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/5acb89b8-c753-4520-a89e-97bb22c12a9e%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...