I wonder that Impact test is not required, unless the thickness is lower that 13 mm. SA-333 belongs to the curve A of UCS-66M.
if impact test is not required, then you can use the available PQR provided that all other essential variables are within range
if impact test is not required, then you can use the available PQR provided that all other essential variables are within range
2016-09-10 16:34 GMT+03:00 Himanshu Panchal <mec4him@gmail.com>:
Dear All,--I want to prepare a WPS for SECVIII Div-1,Material-SA333, MDMT: -46C,Thickness 24 mm.As per vessel drawing there is no impact test and PWHT requirement.I have one PQR without impact test.Can i prepare the WPS based on that PQR who is with out impact test?MDMT of vessel is -46C.Thanks & Regards,Himanshu panchal
http://www.linkedin.com/groups/MaterialsWelding- 122787?home=&gid=122787&trk= anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com .
To post to this group, send email to materials-welding@googlegroups.com .
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/ .CAKHjqA0P6GGCHuozpPeM7P0f5KuaQ Jhh0CiS1MHYdkrFNqp0Kw%40mail. gmail.com
For more options, visit https://groups.google.com/d/optout .
Dr. Georgios Dilintas,
Dipl. Ing. In Aeronautic and Space Engineering
Ph.D in Mechanics of Solids - Computational Mechanics
A.I.S, A.N.I, IRCA Lead Auditor
Welding, Stress Analysis, Corrosion, QA/QC, Failure Analysis, Risk Analysis
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPOi40Azmo7R7B2_btBTgrY8-9Fq6j9%2BQ_VPPSkm488edUALHA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment