Let me explain clearly, now my hydro test pressure is 10 bar. As per ASME Sec VIII Div 1 UG-102 TEST GAGES and ASME Sec V ARTICLE 10 LEAK TESTING T-1030 EQUIPMENT I can use pressure gauge range 1.5 to 4 times of the test pressure i.e. 0-15 Bar to 0-40 barg.
Now my question is can I use these both the gauges (0-15 Bar to 0-40 barg) in a single pressure? If yes please give me code reference.
There is an argument saying that the "minimum of two pressure gauges shall be within 5 % of one another when in use"
Thanks in advance.