Re: [MW:13242] IMPACT TEST IN PTC AT -47 DEG

you have to monitor the actual welding of the coupon and make sure that you are within the parameters of the qualified WPS, if it still fails you can always send the coupon for stress relieving (which is more costly since you have to PWHT your vessel too)

On Mon, Dec 19, 2011 at 10:27 PM, Vivek Pandey <vivek.pande06@gmail.com> wrote:
DEAR EXPERTS

AT this time Iam facing a critcal problem in impact test at minus 47
deg. I have a already existing qualified PQR WITH E 8018G & IMPACT
Tested at -47deg. I have used the same PQR in  vessel production test
at -47deg but this PTC has failed in imapct test of WELD & HAZ at
-47deg we are getting erratic value 10, 12, 90 in weld & 60, 10, 50 in
HAZ

Kindly suggest your opanion  about this problem as soon as possible

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/