On Mon, Dec 19, 2011 at 10:27 PM, Vivek Pandey <vivek.pande06@gmail.com> wrote:
DEAR EXPERTS
AT this time Iam facing a critcal problem in impact test at minus 47
deg. I have a already existing qualified PQR WITH E 8018G & IMPACT
Tested at -47deg. I have used the same PQR in vessel production test
at -47deg but this PTC has failed in imapct test of WELD & HAZ at
-47deg we are getting erratic value 10, 12, 90 in weld & 60, 10, 50 in
HAZ
Kindly suggest your opanion about this problem as soon as possible
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment