Dear All,
Greetings.
A SA 333 GR 6 pipe 6 " NPS x Sch 120 requires simulation PWHT as per sour service requirment
PWHT CYCLE is - 620 deg Celcius for 2 Hours soaking time
simulation cycle is 6 hours.
intial value of Tensile strength is 482 MPA.
Hardness value is 187, 181, 179 BHN.
please inform me whether Tensile strength and hardness will INCREASE or DECREASE after Simulation heat treatment( 3 PWHT cycle)
Thanks & Regards
Asad Azmi
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.