Please review the PQR MTC.. is there any chance that ur mill certs have dual classification...I am sure some of the reputed mfr classify the material as per API and ASME too..
If yes, there is no need for new qualification & but you need to revise the PQR.
Orelse, qualify a new procedure along PTC for Gr2 HAZ impact test..
Alagu
On Thu, 07 Jan 2010 22:19:25 +0530 wrote
>
Friends,
I have come across a typical issue as below,
Material is API 5L X-65 –
S No 1 Gr.2
Impact required at -29 deg.C
Welding as per ASME Sec IX
I have a PQR which is SA 106 Gr B (P1 Gr 1) Impact tested at
-30 deg.C
Can I support this PQR for S1 Gr 2 or P1 Gr 2? My client is
rejected this and asking for PQR which was done on Group 2 materials either on
S1 or P1.
Could you let me know, since my client is seeking evidence
as per Sec IX? How to convince them that Gr 1 impact tested can also be used
for Gr 2 materials.
Regards,
Vasanth
*** WORLEYPARSONS GROUP NOTICE ***
"This email is confidential. If you are not the intended recipient, you must not disclose or use the information contained in it.
If you have received this email in error, please notify us immediately by return email and delete the email and any attachments.
Any personal views or opinions expressed by the writer may not
necessarily reflect the views or opinions of any company in the WorleyParsons Group of Companies."
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/