Dear Javed, Enclosed the details,
Regards,
Nom. Fig. Size Ins. (mm) | Bolting No. x Dia. Ins. | Rec. Bolt Stress lb/in2 | Torque lbf.ft. (Nm) Bolt Lubricant Molykote 1000 (µ = 0.11) | |
36 (900) | 20 x 3 ½" UN8 | 45,000 | 15983 | (21670) |
On 8/2/09, Mohammad Javeed <mmubasharjaveed@gmail.com> wrote:
Dear all
Have a nice day
I need your help about one query regarding torque value. We have a one flange joint of dia 36" RF CL. 900 material A350-LF2.and bolt length is 800mm. As per our client requirement this tightening should be done with hydraulic tensioning system. So what should be the torque value for this flange?
Thanks
M javed
--~--~---------~--~----~------------~-------~--~----~