Skip to main content

[MW:694] Re: 688] Re: PMI TESTING OF SS 304L

Dear Sir,

Unlike using the ED-XRF, there are quite a few areas to be taken care of, in
case you will be using a spark emission portable spectrometer like the
ARCMET. Argon gas of 99.999% min purity is to be used. The gas flow also has
to be controlled as per the instrument requirements, as even setting an
improper flow rate can lead to improper purging, eventually leading to a
deviation in the test results.

Also, the surface to be checked has to be polished using a 60 grit paper (
as this surface finish is used when the equipment is calibrated). This
polished surface should the be checked as soon as possible to avoid any
contamination.

Nowadays, when we use the new models like the ARCMET 8000, we can test flat
as well as round surfaces, as there are adapters available for the same.
Normally, even 1 inch O/D pipes can also be checked using this equipment
with concordant results as per our experience. Of course, for flat surfaces,
there is no problem at all.

Generally, this is a slower process as compared to the XRF, but it yields
quite excellent, accurate and repeatable results.

Regards,

N. Kalyan.
ELCA Laboratories, Thane and Pune.


----- Original Message -----
From: "Raghuram Bathula" <raghurambathula@gmail.com>
To: "Materials & Welding" <materials-welding@googlegroups.com>
Sent: Monday, March 24, 2008 9:39 PM
Subject: [MW:691] Re: 688] Re: PMI TESTING OF SS 304L


>
> you can try ultrahigh pure from the following range, research purity
> may not be avaialble offthe shelf
> RESEARCH PURITY 99.9999%
> ULTRA HIGH PURE 99.999%
> PRE-PURIFIED 99.998%
> ZERO GAS 99.998%
> HIGH PURITY 99.995%
> also surface cleaning of the conatcat area importatnt, consult your
> analyser supplier for further help!
>
> On Mar 24, 3:35 pm, shailesh dave <snd2...@yahoo.com> wrote:
> DEAR Mr. RAGHURAM,
>
> BUT SPARK EMISSION WHAT WE ARE ADOPTING HERE IS ARGON BASED AND MANY
> TIMES I FOUND PURITY OF ARGON IS NOT ENSURED. HENCE I AM RELUCANT TO
> GO FOR SPARK EMISSION FOR PMI OF LOW CARBON SS.
>
> YOUR VIEWS PLEASE.
>
> REGARDS,
>
> S.N.DAVE
>
>
> >


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...