Dear Reddy,Equotip is digital based, unlike Poldy which is mechanical based.
(1) This needs the surface to be smooth, so that rebound shall be proper for its analysis.
(2) The rebound ball is few grams so thickness of the part shall not be an essential criterion. There is facility for angle setting in this instrument, 0deg i.e., is hitting the targets vertically down, and other angle hitting facility exists
(3) Equotip is supplied with thick round calibration block, valves on it are mentioned to match with for calibration purpose.
(4) These are commonly used in maintenance sections of the plants. It only gives the valves of the hardness, so hope no implications of restriction of any codes prevails.
Hope I have answered your questions.
Regards,VenuSingapore================================================================
On Sun, Mar 2, 2008 at 5:26 PM, tamma reddy <tsr_52@yahoo.co.in> wrote:
Dear Friends,Can any one through light on the following queries of digital hardness tester (Eqotip/TIME Group TH 160, HLN-11A/Krautkramer etc.)1. Can weld joint hardness check up with rebound test principle2. what is the minimum thickness of test specimen required for hardness check with above equipment (working on Rebound principle)3. What are the calibration requirement of above instruments4. Are they supported by any project construction codes/ standardsRegards,
T S Reddy
Jamnagar
Chat on a cool, new interface. No download required. Click here.
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---
Sunday, March 2, 2008
[MW:646] Re: Hardness by Equotip
I am not agreeing with point 2 of Mr. Venugopal. At lower thickness [lessthan 10mm] we observed erratic readings. We observed this when checking hardness of attachment welds [This may be due to transfer of some amount rebound energy to the piece]. For more accurate results lower thickness pieces should be attached firmly to higher thickness pieces[Good surface contact is essential] before taking the reading
regards
SRSreddy
Aramco
On 3/2/08, juttada venugopal <jamsvenu@gmail.com> wrote:
Subscribe to:
Post Comments (Atom)
Re: [MW:35289] Welding consumable for S355J2WP material
S355 J2 WP is a weathering structural steel It has better atmospheric corrosion resistance. Use E 8018 - W1/W2 Electrodes This is regular...
-
Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? ...
-
Definition of buttering from ASME Section IX, QW/QB-492 Definitions: Buttering: the addition of material, by welding, on one or bot...
-
Section I. PRINT READING 3-1. GENERAL a. Drawings . Drawing or sketching is a universal language used to convey all necessary information to...
No comments:
Post a Comment