Dear Ellik,
Usage of same PQR depends upon your code of fabrication, Parent & consumable Material used for qualification & thickness of materials.
Some fabrication code does allow to use the same PQR without further impact testing as long the material (parent & consumable) itself qualified to use (upto certain lower temperature).
Sanjeevan
----- Original Message -----From: Elshan FeyzullayevSent: Tuesday, January 05, 2010 8:57 AMSubject: [MW:3965] welding procedure for the material at - 30degree CDear Friends,
I have a welding to do on the material where the service temperature is -30 degree C. I have got a welding procedure which charpy V test was carried out at -20 degree C. can I use this procedure for welding of the material which the service temperature is -30 degree C?
regards,
Elilk.
Windows Live: Make it easier for your friends to see what you're up to on Facebook. --
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.