Saturday, February 19, 2022

Re: [MW:32900] ER309L DMW

you can use it if the service temp is not greater than 300-degree centigrade

On Sat, Feb 19, 2022 at 7:51 PM pradip kumar Sil <pradipsil@gmail.com> wrote:
Yes, you can

On Sat, Feb 19, 2022 at 7:31 PM Tajuddin Mohammed <tajuddinjntu@gmail.com> wrote:
Dear experts,
      Please kindly clarify if we can use ER309L filler wire for dissimilar welding between P1(A106 Gr B) to P8 (A182 F316L) in gas service
 Your valuable suggestion is highly appreciated.

--