Re: [MW:30314] PSV Testing

#600 rating because #600 flange for inlet and #300 is for outlet (exhaust) flange

Regards 
Eyup Tan

iPhone'umdan gönderildi

chiluka venkatramulu <ramuluchiluka@gmail.com> şunları yazdı (24 Ara 2019 06:08):


Dear All,
If PSV having flange rating 300 X 600, which rating is considered for testing Body & Bonnet, as per B16.34.

With Best Regards,
Venkatramulu CH

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAF98%2BdEjRwiKGN8%3DoE-Zqih6F-pDD_KfRr-4QB2ZUEX%2BHoD9gw%40mail.gmail.com.