[MW:30275] PQR shall be tested in Min & Max PWHT (3 Cycle minimum simulation) condition.

Dear Sir's

Client has specified the requirement for testing the PQR in Min & Max PWHT (3 Cycle simulation) condition. As we had pre-qualified PQR with one cycle of 2 Hours soaking. So please suggest how to comply with the requirement & what does this "3 cycle simulation" exactly means?


Regards
Kunal Srivastava

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/3a501189-a776-4557-a36c-bfdc41b280bb%40googlegroups.com.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone