Equipment--- WING WALL PANEL.
MOC--------- Tube-SA213T91+Fin 12Cr1MoV
sizes---------Tube/Dia 42X6mm thick
Fin/ Width 18X6mm thick
After welding, there is lateral bend, To correct it we are doing HOT FLAME CORRECTION below Lower Critical Temp AFTER PWHT.
QUERY --- IS IT ADVISABLE TO DO SO, if not what is procedure.
THANKS®ARDS
KG.PANDITHAN, BE,IWE,AWS-CWI,CSWIP-3.1
Adviser/International Welding Engineer
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.