Hi,
It will not qualify…
As F no & A No are not only the criteria for acceptance…
F&A grouping are majorly for welder / operator qualification and not to consider in PQR.
Need to go for a fresh PQR.
Thanks & Regards,
Lakshman Kumar B,
+91 9440031459.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of r.vroom
Sent: Friday, August 05, 2016 8:01 PM
To: Materials & Welding <materials-welding@googlegroups.com>
Subject: [MW:25195] PQR Qualification.
All,
Please advice me in the following.
ASME IX :2013
Weld coupon base material P8 (ASTM A240 TP 316) to P1 (S333 Gr. 6)
FCAW: Filler metal Bohler CN 23/12 Mo PW-FD (E309LMoT1-4)
Does this PQR qualify a weld joint P8 (ASTM A240 TP 304) to P8 (ASTM A240 TP 304)
by changing filler metal into E308LT1-1 for both F No. 6 and A No. 8
Follow Table QW 255 Ø P-number qualified article 403.11 -> article 424.1 I should say no, but am I right ????
Diameter and thickness are in range.
Thank you.
--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/83ce3674-8b7a-42d2-b8f6-98aa0cdb35db%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment