Skip to main content

[MW:25314] Re: Re: % Ferrite & FN measurements of Duplex Stainless steel welds

Dear Mr. Pradip,

Many thanks for your valuable suggestion and references.

It was suggested by Consumable manufacturer  to use Super duplex filler metal as we were unable to pass corrosion test required by SAES-W-016.

Regards,
Mohammed Azharuddin

On 25 August 2016 at 06:32, pgoswami <pgoswami@quickclic.net> wrote:

Mr Azharuudin,

 

Your client is correct. The established formula for conversion is : % Ferrite= 0.7 x Ferrite No(FN)  or FN= 1.4 X % Ferrite.

 

Please see the highlighted texts in the attached documents of Fisher Ferrito scope for your information. Up to 28-30  abstract values both FN & % Ferrite runs equal. At higher values the FN is more in number that %Ferrite.

 

If you look at the ferritoscope MP-30  training document, when you plot the lines intersecting the centerline of the curve(Page-4), it's clearly visible at higher % Ferrite values, the numerical values of  Ferrite No(FN) is more.

 

Also it would be advisable to cross check the Lab reading (computed as per ASTM E-562) with Fisher Ferrito scope also.  As claimed in the  Ferrito scope catalogue(marked with a arrow)  results could be correlated both in % Ferrite  7 Ferite No.

 

Use these information to straighten out the calculation and get your PQR through.

 

Also a question, what prompted you use Super Duplex Welding filler wire for DSS UNS-31803??  Appreciate  your response.

 

Thanks.

 

 

Pradip Goswami, P.Eng,IWE
Independent Welding & Metallurgical Engineering Specialist ,
Ontario,Canada.
ca.linkedin.com/pub/pradip-goswami/5/985/299

pgoswami@quickclic.net

pradip.goswami@gmail.com

 

 .


From: Pradip Goswami [mailto:pradip.goswami@gmail.com]
Sent: Wednesday, August 24, 2016 9:49 AM
To: Anasua Goswami
Subject: Fwd: Re: % Ferrite & FN measurements of Duplex Stainless steel welds

 

---------- Forwarded message ----------
From: "Mohammed Azharuddin" <humaidazhar@gmail.com>
Date: Aug 24, 2016 3:19 AM
Subject: Re: % Ferrite & FN measurements of Duplex Stainless steel welds
To: "Pradip Goswami" <pradip.goswami@gmail.com>
Cc:

Dear Mr. Pradip,

 

Please see attached client specification.

 

We reported ferrite in both vol% and FN value.But the correlation what client is asking ( 70% FN VALUE= VOL% FERRITE ) we are unable to get it.Moreover it is a thumb rule I believe.

 

Thanks

Mohammed Azharuddin

 

On 23 August 2016 at 19:39, Pradip Goswami <pradip.goswami@gmail.com> wrote:

Could you scan and email the entire spec.Your client is correct asking ferrite to be reported in volume or % ferrite. Thx

 

On Aug 23, 2016 12:29 AM, "Mohammed Azharuddin" <humaidazhar@gmail.com> wrote:

Reported values and client comments attached

 

I believe that 70%FN = VOL% FERRITE is a rule of thumb [pgoswami] --- This is not a rule of thumb. This conversion is arrived at after conducting numerous tests and correlations of numerous data on weld  ferrite content.

 

Actual correlation must be established from the measurements during PQR qualification

 

 

 

These readings are wrong. Please see the explanations above.

 

 

On 23 August 2016 at 07:25, Mohammed Azharuddin <humaidazhar@gmail.com> wrote:

Dear Experts,

 

We have performed qualification on Duplex stainless steel BM UNS 31803 welded to itself with filler ER2594. Shielding gas AR+2% nitrogen

 

Ferrite measurements of welds were carried out as per ASTM E562 and AWS A4.2.

 

Client has rejected these values as the correlation is not appropriate.See below reported values and client comment.

 

From client point of view ,It should have been like VOL % FRRITE = 70% FN VALUE.

 

Your valuable advise will help us to save this WPS from being rejected.

 

Many Thanks

 

Regards,

Mohammed Azharuddin

 

 


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAEeeqa%2BySKK9y4SJ1GXXg%3DBwmYBjszDYtVTH%3D%2BPAUjB4OH0DbA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...