Skip to main content

[MW:25313] RE: Re: % Ferrite & FN measurements of Duplex Stainless steel welds

Mr Azharuudin,

 

Your client is correct. The established formula for conversion is : % Ferrite= 0.7 x Ferrite No(FN)  or FN= 1.4 X % Ferrite.

 

Please see the highlighted texts in the attached documents of Fisher Ferrito scope for your information. Up to 28-30  abstract values both FN & % Ferrite runs equal. At higher values the FN is more in number that %Ferrite.

 

If you look at the ferritoscope MP-30  training document, when you plot the lines intersecting the centerline of the curve(Page-4), it’s clearly visible at higher % Ferrite values, the numerical values of  Ferrite No(FN) is more.

 

Also it would be advisable to cross check the Lab reading (computed as per ASTM E-562) with Fisher Ferrito scope also.  As claimed in the  Ferrito scope catalogue(marked with a arrow)  results could be correlated both in % Ferrite  7 Ferite No.

 

Use these information to straighten out the calculation and get your PQR through.

 

Also a question, what prompted you use Super Duplex Welding filler wire for DSS UNS-31803??  Appreciate  your response.

 

Thanks.

 

 

Pradip Goswami, P.Eng,IWE
Independent Welding & Metallurgical Engineering Specialist ,
Ontario,Canada.
ca.linkedin.com/pub/pradip-goswami/5/985/299

pgoswami@quickclic.net

pradip.goswami@gmail.com

 

 .


From: Pradip Goswami [mailto:pradip.goswami@gmail.com]
Sent: Wednesday, August 24, 2016 9:49 AM
To: Anasua Goswami
Subject: Fwd: Re: % Ferrite & FN measurements of Duplex Stainless steel welds

 

---------- Forwarded message ----------
From: "Mohammed Azharuddin" <humaidazhar@gmail.com>
Date: Aug 24, 2016 3:19 AM
Subject: Re: % Ferrite & FN measurements of Duplex Stainless steel welds
To: "Pradip Goswami" <pradip.goswami@gmail.com>
Cc:

Dear Mr. Pradip,

 

Please see attached client specification.

 

We reported ferrite in both vol% and FN value.But the correlation what client is asking ( 70% FN VALUE= VOL% FERRITE ) we are unable to get it.Moreover it is a thumb rule I believe.

 

Thanks

Mohammed Azharuddin

 

On 23 August 2016 at 19:39, Pradip Goswami <pradip.goswami@gmail.com> wrote:

Could you scan and email the entire spec.Your client is correct asking ferrite to be reported in volume or % ferrite. Thx

 

On Aug 23, 2016 12:29 AM, "Mohammed Azharuddin" <humaidazhar@gmail.com> wrote:

Reported values and client comments attached

 

I believe that 70%FN = VOL% FERRITE is a rule of thumb [pgoswami] --- This is not a rule of thumb. This conversion is arrived at after conducting numerous tests and correlations of numerous data on weld  ferrite content.

 

Actual correlation must be established from the measurements during PQR qualification

 

 

 

These readings are wrong. Please see the explanations above.

 

 

On 23 August 2016 at 07:25, Mohammed Azharuddin <humaidazhar@gmail.com> wrote:

Dear Experts,

 

We have performed qualification on Duplex stainless steel BM UNS 31803 welded to itself with filler ER2594. Shielding gas AR+2% nitrogen

 

Ferrite measurements of welds were carried out as per ASTM E562 and AWS A4.2.

 

Client has rejected these values as the correlation is not appropriate.See below reported values and client comment.

 

From client point of view ,It should have been like VOL % FRRITE = 70% FN VALUE.

 

Your valuable advise will help us to save this WPS from being rejected.

 

Many Thanks

 

Regards,

Mohammed Azharuddin

 

 

Comments

Popular posts from this blog

Re: [MW:34105] SA266 GR4N 4 Cycle SPWHT

Hi,  You are correct, Minimum refers to the one cycle for which this part will expose until final work shop PWHT. hence mill test certificate shall include this.  Max. SPWHT, refers to additional cycles of heat treatment that are reserved for future repairs during equipment lifetime.  Again, these simulated no. Of cycles shall be specified in MTC.  The idea is we need to make sure that steel mechanical properties are not compromised upon exposure to multiple repairs (i e 4 cycles in your case).  One could say, if steel is subjected to 4 cycles and is ok, then it should by defacto be good for one cycle, yet, this is wrong assumption cause mechanical problems and microstructure of materials varies accordingly based on no. Of cycles for which material will expose. This is apparent in alloy steel and especially for impact test values as an example.  In your case, this forged CS with properties before PWHT can be understood to be " as forged" condition (i.e. Wit...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...