In Table QW-253 of Section IX in ASME BPVC, the impact test temperature is not listed as a WPS variable (neither essential, nor supplementary essential, nonessential). There are several Supplementary Essential Variables which are applicable in case impact test is a requirement, but impact test temperature and impact test requirements are not included in Section IX.
Impact test requirements are specified in the Design and Construction Code Section.
Assuming that in your case Section VIII-1 applies and your material is a CS, then you have to do following:
- You have to check if you can get an impact test exemption following the rules of UG-20(f).
- If you cannot get an exemption, then you have to implement the requirements of UG-84.
- Pay attention to the requirements of UG-84(c)(5). Depending on the width of the specimen along the notch, the impact test may be conducted at a temperature lower (colder) than the MDMT (see table UG-84.2).
- For details of PQR Impact test you have to read carefully UG-84(f)
- I would advise to read carefully all UG-20 and UG-84 and then UCS-65,-66 before you finalize your PQR
best regards
Dr. Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
I&F REGIONAL TECHNICAL MANAGER
BUREAU VERITAS PIRAEUS - GREECE
Tel: +30 210 40 63 113 /4 /5
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
"Vanchinath S.A." ---11/09/2015 07:03:34---No. Impact test at minus 45 deg C will have to be carried out. On 11 Sep 2015 11:46, "Mahesh Mirje"
From: "Vanchinath S.A." <vanchinaths@gmail.com>
To: materials-welding@googlegroups.com
Date: 11/09/2015 07:03
Subject: Re: [MW:23447] WPS REVISION
Sent by: materials-welding@googlegroups.com
No. Impact test at minus 45 deg C will have to be carried out.
On 11 Sep 2015 11:46, "Mahesh Mirje" <mahesh.mirje41@gmail.com> wrote:
- Hi expert's,
I have PQR with electrode E7018, AND IMPACT tested at -30deg. Lets say Observed energy values 20J
Can I make wps with E7018-1, FOR IMPACT REQUIRMENT at -45 deg.required energy values 20j,
AS per ASME weld metal produced by 7018-1, will provide 20j at -45 deg.
And HAZ ENERGY VALUES CAN BE CONTROLLED BY RESTRICTING HEAT INPUT.
Pls, clarify can I prepare wps for 7018-1 at -45 by restricting heat input as same used in 7018 PQR.
Regards
Mahesh
--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/c1f31c03-f8f6-4fe8-9f5b-7212237bffe4%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CA%2B6Tn1KbHMWZfY91WVvm4vdjbqZsbLp0iXC%2BFzw8CbPYCOHRGw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com