Re: [MW:23395] PWHT thickness requirement as per ASME B 31.3 2014

ASBA has issued information bulletin to bring awareness and provide guidance to designers, owners and fabricators regarding the use of ASME B31.3-2014 Process Piping which was published 27 February 2015.
pl. refer to the link

On Tuesday, September 1, 2015 at 1:03:14 PM UTC+4, MW wrote:
PWHT is exempted for all thicknesses and weld types of P-No 1 base material, subjected to meeting the requirements of  Notes in Table 331.1.3 (such as preheat and multiple layer welds...).

On 1 September 2015 at 12:24, S.Mohammed <mohd52100@gmail.com> wrote:
Dear all,

As old ASME B31.3-2012  we know it was above 19mm req pwht,

now i read ASME B31.3-2014,little confused me with pwht exemption and pwht requirements and control thickenss 331.1.3?

q1- what is thik req for pwht for P1 as per b31.3 2014 ?

q2 : for P1,mentioned more than 25mm thk and 95C preheat exemption from pwht so less than 25mm not require pwht ?


regards,
mohd.


--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/73339cdd-57e6-478f-87e1-2b437c1c2d13%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...