hi

PT and MT can detect surface and sub surface defects whereas vaccum box testing after applying soap water produce bubbles if there is leak (whatever discontinuity it may be crack, porosity) and you can examine the area carefully to find the defect which is more effective.

On Mon, May 7, 2012 at 4:21 PM, M S <striarc@gmail.com> wrote:

Please provide technical support:-

What is the difference between Vacuum box test(for leak detection) and PT(for surface discontinuity detection)?

PT can detect all the surface discontinuity as well and MT can detect surface and slightly subsurface discontinuity also, but why API 650 prefers Vacuum box test instead of PT for Carbon steel-tank bottom plate welding?

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Thanks & Regards
Srirammadhan
Piping/painting inspector
Great drill Chaaya
Great Ship
Hamriyah Free zone, UAE


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...