[MW:9038] Re: 9027] Re: Stress Corrosion Cracking Test

Dear Pradip,

I just saw your reaction in this topic, I don't know why but I didn't
receive it in my private mail box. So therefore I didn't receive the
attachments to this message you refer to.
Can you please send me these documents again directly to my personal
mailbox?
I will ask my previous colleagues at Exova laboratory (formerly
Bodycote) if one of their laboratories as experience with this G36 SCC
test and CaCl2 solution.
Problem is only that they have holiday because of Newyear on this
moment so first possibility for that will be January 3th.

Wish you all a happy New year.

Best Regards

Herman Pieper

On 30 dec, 22:41, "pgoswami" <pgosw...@quickclic.net> wrote:
> Mr.. Herman and Mr Rana,
>
> Attached are some documents which references Chloride SCC in CaCl2 solution.
>
> ASTM G-36, is a very long established standard for chloride SCC. I have
> come across of some literatures reporting that MgCl2  test being aggressive
> on a number of  stainless steels.Hence a more moderate one e.g CaCl2 test is
> followed by the industry.
>
> Many manufacturers of duplex SS refers  to SCC in CaCl2 media. However to
> the best of my knowledge no ASTM standard cross refers CaCl2 media for
> chloride SCC.
>
> Mr. Herman,if  you have more information through your association with
> various labs/testing facilities,may put up the updates.
>
> Please see the extracts from G-36 on the pros and cons of MgCl2 test.
>
> Thanks
>
> Pradip Goswami,P.Eng.,IWE.
> Welding & Metallurgical Specialist & Consultant
> Email-pgoswami@ <mailto:sympatico.capgosw...@quickclic.net> sympatico.ca,
> pgosw...@quickclic.net
>
> G-36 extracts:-
>
> *      
>
>         This practice describes a procedure for conducting stress-corrosion
> cracking tests in a boiling magnesium chloride solution. Although this test
> may be performed using various concentrations of magnesium chloride, this
> procedure covers a test solution held at a constant boiling temperature of
> 155.deg°C (311.deg°F).
>
> *      
>
>         The boiling magnesium chloride test is applicable to wrought, cast,
> and welded stainless steels and related alloys. It's a method for detecting
> the effects of composition, heat treatment, surface finish, microstructure,
> and stress on the susceptibility of these materials to chloride stress
> corrosion cracking
>
> *      
>
>         Boiling magnesium chloride may also cause pitting of many stainless
> alloys. This leads to the possibility of confusing stress-corrosion failures
> with mechanical failures induced by corrosion-reduced net cross sections.
> This danger is particularly great when small cross section samples, high
> applied stress levels, long exposure periods, stress-corrosion resistant
> alloys, or a combination thereof are being used. Careful examination is
> recommended for correct diagnosis of the cause of failure.
>
> *      
>
>         For most applications, this environment provides an accelerated
> method of ranking the relative degree of stress corrosion cracking
> susceptibility for stainless steels and related alloys in aqueous
> chloride-containing environments. Materials that normally provide acceptable
> resistance in hot chloride service may crack in this test. The test may not
> be relevant to stress-corrosion cracking in polythionic acid or caustic
> environments.
>
>   _____  
>
> From: materials-welding@googlegroups.com
> [mailto:materials-welding@googlegroups.com] On Behalf Of
> jignesh.r...@Linde-LE.com
> Sent: Thursday, December 30, 2010 7:48 AM
> To: materials-welding@googlegroups.com
> Subject: Re: [MW:9027] Re: Stress Corrosion Cracking Test
>
> Dear Mr. Herman
>
> Thanks for quick reply.
>
> It is not mistake in specification. Specification categorically demands 40%
> CaCl2 solution (Ph -6.5, Testing time - 500 Hrs., 100 Deg Boiling,
> Acceptance criteria - Stress to cause rupture shall exceed 0.85 times UTS,
> as per ASTM G 46)
>
> Further, specification calls for  MgCl2 solution for Duplex grade as per G
> 36.
>
> Since, aberrant solution is being asked for testing as per ASTM G 36,
> precisely the question was put in this forum.
>
> Request all team members to share views of chloride stress corrosion test of
> super Duplex ( S 32750)
>
> With Best Regards,
>
> Jignesh R Rana
> Manager - QA & QC
>
> Linde Engineering India Pvt. Ltd.
> 38, Nutan Bharat Society, Alkapuri, Vadodara 390007, India
> Tel.: +91 265 3056789, Fax: +91 265 2335213 , Mobil:  +91 90999 86019
> jignesh.r...@linde-le.com,www.linde-india.com
>
> This e-mail is confidential. If you are not the intended recipient, please
> notify us immediately. You should not disclose its contents to any other
> person nor use it for any purposes.
>
> hpi001 <pieper-...@kpnmail.nl>
> Sent by: materials-welding@googlegroups.com
>
> 30/12/10 16:53
>
> Please respond to
> materials-welding@googlegroups.com
>
> To
> "Materials & Welding" <materials-welding@googlegroups.com>
>
> cc
>
> Subject
> [MW:9019] Re: Stress Corrosion Cracking Test    
>
> Why does anyone asking for ASTM G36 with an aberrant test solution?
> Probably there will be no big difference between both solutions
> because Chloride is the important part in this test but by choosing
> for CaCl you won't have any reference or acceptance criteria or is
> this also specified in the project specification? Can it be a mistake
> in the specification as well?
>
> Best Regards,
>
> Herman Pieper
>
> On 30 dec, 11:44, jignesh.r...@Linde-LE.com wrote:
>
>
>
>
>
>
>
>
>
> > Dear Members,
>
> > One of our project specification calls for Chloride Stress Corrosion
> > Cracking as the ASTM G 36 with CaCl2 (40%) solution for super Duplex
> > Stainless steel ( S 32750)
>
> > ASTM G- 36 is based on MgCl2 solution.
>
> > Does any one having experience with SCCT with CaCl2 solution ?
>
> > With Best Regards,
>
> > Jignesh R Rana
> > Manager - QA & QC
>
> > Linde Engineering India Pvt. Ltd.
> > 38, Nutan Bharat Society, Alkapuri, Vadodara 390007, India
> > Tel.: +91 265 3056789, Fax: +91 265 2335213 , Mobil:  +91 90999 86019
> > jignesh.r...@linde-le.com,www.linde-india.com
>
> > This e-mail is confidential. If you are not the intended recipient, please
> > notify us immediately. You should not disclose its contents to any other
> > person nor use it for any purposes.
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg athttp://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg athttp://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...