Tuesday, August 16, 2011

Re: [MW:12227] Gas purging for 12Cr1MoVG

refer para 7.3 of API RP 582

On Sun, Aug 14, 2011 at 7:20 PM, Endri Prasetyo
<endri.prasetyo@gmail.com> wrote:
> Dear Mr. Raghuram,
> Can you please share here in which statement of API 582 that mentions about
> it?
> Thanks and regards,
> Endri
>
> On Sun, Aug 14, 2011 at 2:55 PM, Raghuram Bathula
> <raghurambathula@gmail.com> wrote:
>>
>> i guess the %Cr <2.25 in this material, in that case back purging is
>> not required as long you have a qualified PQR without purging.
>> Generally purging is recommended for materials with Cr >2.25% (refer
>> API 582).

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34916] Applicability of Impact requirement as per ASME B31.3

Dear All, Design code – ASME B31.3, Welding Code- ASME BPVC SEC IX Material  to be used used during Fabrication - SA 333Gr6 (P No.1 G...