Skip to main content

Re: [MW:35508] WPS for Furnace PWHT

Yes, performing furnace PWHT on any joint that was welded using a WPS not qualified with PWHT violates Clause 331.1.6(b) of ASME B31.3. It constitutes a quality non-conformance, even if the individual weld is below the threshold thickness for mandatory PWHT.

BR, 

Deerendra 


On Sat, 5 Apr, 2025, 18:49 Prakash Kumar Bontra, <prakashbontra@gmail.com> wrote:

As per ASME B31.3, Clause 331.1.6 (b):
Any required PWHT shall be carried out in accordance with the qualified WPS.

For furnace PWHT involving spools of different diameters and varying thicknesses, all weld joints subjected to PWHT must be welded using a WPS qualified with PWHT. This requirement remains applicable even when the individual joint thickness is less than 20 mm, despite the code-specified threshold of greater than 20 mm for P1 materials, as outlined in Table 331.1.1 of ASME B31.3 (2008).

Therefore, performing furnace PWHT on any joint that was welded using a WPS not approved for PWHT constitutes a non-conformance with the applicable quality requirements. Do you agree? If not please elaborate.

Prakash


On Sat, Apr 5, 2025 at 7:52 AM Hareesh K V <hareesh.kitco@gmail.com> wrote:
Dear Sir,

I am not clear about the question.

Is the question is "The welding is done without following a WPS having  PWHT and actually the joints need the same" is it?

May I know the material ?

Also if it is of Carbon Steel material, is PWHT requirment is there based on design or based on ASME 31.3?

Regards,

Hareesh K V

On Mon, 27 Jan, 2025, 11:57 am Prakash Kumar Bontra, <prakashbontra@gmail.com> wrote:
For furnace PWHT as per ASME B 31.3 all the joints in the spool (1" to 36") need PWHT approved WPS and where to refer?

Prakash Bontra

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CANeLWoNy0URXS9X7TEvvZRVe4V-1LNPKwidHJ097fDyPAjyh7Q%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to a topic in the Google Groups "Materials & Welding" group.
To unsubscribe from this topic, visit https://groups.google.com/d/topic/materials-welding/oPoxrZeCuSA/unsubscribe.
To unsubscribe from this group and all its topics, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAEv1fk_qTuLX3BbXwWEmjZYkHEKJg5fYEQ4n3tV28CtXxXG8DA%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CANeLWoNcLHBndkp%3DRS5noKQnJLek4y7Ku9xuQHgAK7-WcZJ%2B4A%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAG0nF9HGKViUYO-Uj_uXgPb3e4fVkX7ZKeMTkbUD9t8XZ9osBw%40mail.gmail.com.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .