Re: [MW:33653] ER-70S-2 and ER70S-6


code is not restricted  to use these consumables  but WPS shall refer the same consumable which to be used at the time of welding , 
you need to revise this WPS using the same PQR and submit it for client approval before proceeding for welding , u need to mention consumable type which you wants go for 

check client Specification for consumable restrictions against PQR qualified with.

Techinca part :   each consumable has its own advantages but ER70S-6 is better  for strength and impact applications , one  must know that Mn provides better strength and toughness to the weldments. So, any loss of Mn from the weld deposit will actually reduce the strength , more silicon present in ER70S-6 consumable will make a good  weld bead appearance.

Regards, 
Srinivas Rao
Welding Engineer 

On Wed, Nov 2, 2022 at 7:08 AM Kannayeram Gnanapandithan <kgpandithan@gmail.com> wrote:
no restrictions  but pl verify the BTC for ER 70S-6 chemistry which Mn, Si shall be within A1 maximum limit. (Mn-1,6, Si-0,8)

On Tue, Nov 1, 2022, 2:47 PM Muhammad Azeem <azeem7999@gmail.com> wrote:

Hi Zafar,
As per approved WPS you need to follow the same filler wire or electrode, You can switch for welders within the same F number and can use any filler wire.
For WPS strict to utilized as per Actual PQR.

Regards,

Muhammad Azeem Iqbal
Welding Inspector Aramco Approved
053110-8577/0554453626/0590071467




On Mon, 31 Oct 2022 at 06:12, Chaudhary Zafar Iqbal <chzaiqbal88@gmail.com> wrote:
Respected Member of this Group ,

As per approved wps ER70S-2 required to use .


Any code restrictions to use ER70S-6 instead of ER-70S-2 ?

Any code restriction and reference to change the WPS ?

Waiting for your valuable comments .

Regards,
Zafar 
00966544639978

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAP9k9Xfz8xCCsA_t9CeOMw_Z506BBi5sX5wjT8SUuBrS9JrsZQ%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHqH7yCo0g6%3DZQJ82zq0zhu9fPU%3DLsgQcu0AFDbFdUvoo08_dg%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAJzm4eP3CbwCre5ZZp0hrmooO1A%2BRaf6JD-1kn2hd2rw%3DxRiRg%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHdRSOO8PWAoHz1V9KxT%3DnunWJts_OP_y877YqKi69eczNv7Gg%40mail.gmail.com.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...