Dear SIr
Do As much as the Weaving wish to do during establishment of PQR report the same on the witness sheet. Once the test reports are Ok. Mention the weaving range on WPS ( Such as max. Weaving allowed 20 mm.). I do the same thing and don't face any issues from customers as well as TPI Because It is tested and reported on PQR .
Regards
Atul Jha
On Sun, Jun 28, 2020 at 9:48 PM Aakash <harenathjha@gmail.com> wrote:
--Hello Experts,What is the technical explanation of : "weaving shall be three times of electrode core diameter"or any code reference ?Regards