Greetings,
Please check attachment for the requirements inside kingdom.
Regards
Muneeb
On Mon, Aug 20, 2018, 2:18 PM Temburu Chiranjeevulu <chiru.qaqc@gmail.com> wrote:
--Dear Experts,1. WPS/PQR (P NO: 1, Group No-1 to P NO: 1, Group No-1 ) is available with contractor
2. Pipe material: ASTM A333 Gr.6 (P No: 1, Group No: 1)Flange/Fitting material: ASTM A350 Gr.LF2 CL.1 (P No: 1, Group No: 2)WPS/PQR ( P NO: 1, Group No-1 to P NO: 1, Group No-2 ) is not available with contractor
3. Charpy "V" notch test to be doneMy query is1. Can I use WPS/PQR (P NO: 1, Group No-1 to P NO: 1, Group No-1 ) for welding between P NO: 1, Group No-1 to P NO: 1, Group No-2 ?2. Is it possible to take sample from pipe to flange test coupon ?
CHIRANJEEVULU TEMBURU l Inspection Engineer-Mechanical I +918790956353.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment