Dear Experts,
2. Pipe material: ASTM A333 Gr.6 (P No: 1, Group No: 1)
Flange/Fitting material: ASTM A350 Gr.LF2 CL.1 (P No: 1, Group No: 2)
WPS/PQR ( P NO: 1, Group No-1 to P NO: 1, Group No-2 ) is not available with contractorMy query is
Can I use WPS/PQR P NO-1, Group NO-1 (PLATE) to P NO-1, Group NO-2 (PLATE) for welding of ASTM A333 Gr.6 (P No: 1, Group No: 1) to ASTM A350 Gr.LF2 CL.1 (P No: 1, Group No: 2) ?
Please give suggestions, Is it possible in accordance with ASME Section-IX ?
CHIRANJEEVULU TEMBURU l Inspection Engineer-Mechanical I +918790956353.