[MW:28162] i am looking for acceptance criteria according to asme section ix for visual examination

sorry i think there is no acceptance criteria given for visual inspection. but during visual inspection dimensional and surface should be free of porosity . crack . undercut .incomplete penetration n fusion. than for consider its relevant or non relevant u have to do lpt.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35507] WPS for Furnace PWHT