Re: [MW:26201] ASME AND AWS D 1.1 clarification for wps qualificatioon

Dear Saravanan,
Construction codes are normally indicated in the Project Specification or FEED documents, data sheets, PMS and GAD's.

In case if it is not there in the above documents,  prepare a QC Procedure or Method Statement for fabrication of structural works indicating AWS D1.1 as a construction code, submit to Client for approval.

Regards
P Govindan

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANiuf9eziVOu6Egq6pNPr3J1NOfFX0iZ6VTmSOxcZBrOjH12_w%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...