Re: [MW:23416] Procedure Qualification Hot wire vs Cold wire TIG

yes , you can
Pl. refer attachment 

On 7 September 2015 at 13:52, FAIRON Luc <luc.fairon@cmigroupe.com> wrote:

Base material is stainless steel and there is no impact requirement (no supplementary essential variable)

 

Luc Fairon

 

De : materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] De la part de Raghuram Bathula
Envoyé : lundi 7 septembre 2015 11:46
À : Materials-Welding
Objet : Re: [MW:23414] Procedure Qualification Hot wire vs Cold wire TIG

 

is Impact testing required? it will effect other parameters, for e.g QW 409.1 (travel speed and amp are higher in case of hot wire)

 

On 7 September 2015 at 13:25, FAIRON Luc <luc.fairon@cmigroupe.com> wrote:

I have got a PQR qualified for orbital TIG welding (automatic) with cold wire. Does it qualify for orbital TIG welding with hot wire, all other thinks remaining unchanged ? In my opinion yes, but I am not sure. Applicable construction code is ASME. Welding qualifications are per Section IX.

Regards

 

Luc FAIRON
Welding Engineer

 

 

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADxVub%3DLvcSkXb_7HMdAO5kPi7jYn_jjFwACcCz1g6m5nt-wpw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...