Tuesday, July 1, 2014

Re: [MW:21306] Use of Filler Wire E71T-1C for vessel with MDMT -29°C

Hi
 
Due to variation in Charpy V notch Impact values most of client specs. restrict the use of FCAW process in process equipments.
You can check your project specs. and decide.
 
Regards
 
Prem Nautiyal
9769316004


On Tuesday, July 1, 2014 1:30 PM, veera raghava kommisetti <kommisetti@gmail.com> wrote:


No Prohibition for use of FCAW from code.
But many client specification prohibit use of FCAW on Pressure Vessels.


On Tue, Jul 1, 2014 at 7:00 AM, Mhaskar Aly <mhaskar.aly@gmail.com> wrote:
Dear Friends,
 
We have
·         FCAW filler wire E71T-1C (Impact tested @ -20°C as per MTC)
·         Vessel (SA516 Gr 70; MDMT -29°C; Impact test exempted)
 
Can we use this filler wire for welding on above vessel for:
1.       Nozzle to Shell weld
2.       RF Pad to Shell weld
3.       Vessel external Attachments with pad.\
4.       Saddle Pad to Shell weld
 
Kindly provide Code Reference
 
Thanks & regards
 
Ali Mhaskar,
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to mailto:materials-welding%2Bunsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.


No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...