Friday, February 7, 2014

[MW:20036] Query for HT condition for 50Ton Ranshorn Hook MOC: 20C15

Material of Construction of 50 Ton hook: 20C15 complying to IS 4367 code, implies final condition Harden & Tempered.
Hook designed as per Ramshorn hook IS 5749-1970 calls for Normalizing heat treatment after forging and before testing.
A vendor has conducted Normalizing + Hardening (quenching) + tempering followered by testing.
 
Now the Inspection Agency is not accepting the Hook, on the basis that the hook is Q+T.
 
Has anyone experience in the above.
 
 
 
Thank You,
 
Regards,
Bosco A. D’Souza
Welding Engineer
 
 

No comments:

Re: [MW:35374] Material Certification 3.1 / 3.2/2.2--EIL India

Dear Perumal, I answer the same but got one more question where it is written that TPI witness is mandatory? -- https://materials-...