Saturday, May 5, 2012

Re: [MW:14190] HOT TAPPING OF LPG PIPE LINES

Dear Venkat,
recently we have done the Hot-tap for our project, the hot tap crew & their safety team will assess the area, condition of the site, as well as your emergency contingency plan based on the risk assessment.
you need to have basically following in your hand.
1) Hot-Tap package (hot-tap procedure, welding procedure, hot-tap calculation, UT reading, ISO, P&ID, MTO etc).
2) Emergency contingency plan.
3) Split tee hydro test reports.
4) Spool hydro test report. etc.
 
Warm Regards'
Rafeeq Ur Rahman

From: N VENKATESWARA PRASAD <weldengr.velosi@gmail.com>
To: materials-welding <materials-welding@googlegroups.com>
Sent: Thursday, 3 May 2012 11:16 AM
Subject: [MW:14177] HOT TAPPING OF LPG PIPE LINES

Dear Friends,
 
We are planning to do  hot tapping of LPG pipe lines with wall thcikness of 9 mm.  Does any body have experience with the same, please share.  We have qualified the procedure, but  there are apprenhensions regarding safety in hot tapping of LPG pipe lines
 
Regards
 
Venkat

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...