Any weld for carbon steel (P1)with thickness above 20 mm require PWHT inaccordance with ASME B 31.3.
So in your case it is YES.
Thanks & Reagrds
J.Gerald Jayakumar
00968-93281596
J.Gerald Jayakumar
00968-93281596
From: mauricio padilla <mauricio_padilla_f@yahoo.com>
To: Materials & Welding <materials-welding@googlegroups.com>
Sent: Tuesday, December 20, 2011 3:13 AM
Subject: [MW:13234] B31.3 PWHT
-- To post to this group, send email to materials-welding@googlegroups.comTo unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.comFor more options, visit this group's bolg at http://materials-welding.blogspot.com/The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To: Materials & Welding <materials-welding@googlegroups.com>
Sent: Tuesday, December 20, 2011 3:13 AM
Subject: [MW:13234] B31.3 PWHT
Dear, Please I need your Help, about ASME B31,3. I need to know if it is required PWHT. CASE: Pipe A106 Grb (PN 1) wall thickness 0.844" B31.3 Chapter V Table 331.1.1 According to table 331.1.1 really is it necessay PWHT. Please tell me Is it correct?. Best regards Mauricio |
No comments: