I do agree that Heat Input of SAW will be having a bearing on the root HAZ of A333Gr.6 material.
 
Moreover the below points also need to be considered.
 
1. Specification guarantees impact test values only at -45degC
2. Specification guaranteed for Base material impact values are 18J and single value of 14J.
 
So please check the suitability of the material ASTM A333gr.6 for your application.
 
Another option is run SMAW 2 or 3 runs after GTAW before SAW to compensate for the Heat Input.
 
Lower preheat doesn't affect your impact values, lower the preheat better the impact values due to grain refinement.
 
Thanks & Reagrds
 
J.Gerald Jayakumar
00968-93281596
From: pgoswami <pgoswami@quickclic.net>
To: materials-welding@googlegroups.com
Sent: Sunday, December 18, 2011 12:43 AM
Subject: [MW:13223] RE: 13222] Impact test fail with A333 Gr6

Hi Solomon,
 
The problem looks to be in the the HAZ (FL & FL-2mm) on the pipe (SA 336 Gr-6) not much  in the weld metal or on the flange SA 350 LF2. A few things to look for :-
  1. What were the impact properties of the pipe, impact temperature vs. impact values
  2. What were the impact properties of the GNAW filler,impact temperature vs. impact values
  3. Did you have any control on the heat input of the first two passes of GTAW. If so how much was the  calculated heat input??
  4. What was the heat input in the first 2 layers of Submerged Arc Welding (SAW). It's better to be within 1.5-2.0 Kj/mm max  range for the first two layers.
  5. In a single Vee  weld the  amount of dilution and effect of the heat input on the base metal & HAZ would be major in the first 2-3 passes. In this case the first two layers were done by GTAW. However as SAW is  a high heat input process, it may substantially over temper the subsequent layers of the weld or the adjacent HAZ.So it would be advisable to control the heat input in the first 2 passes of SAW.
The worst area look to be the root of the weld and the adjacent HAZ on  SA 333 Gr 6.If pipes are properly heat treated for guaranteed impact and so is the welding welding consumable  then the culprit would he the heat input.
 
Appreciate your thoughts and results of further follow-up on this issue.
 
Thanks.
 
Prada Goswami,P.Eng.IWE
Welding & Metallurgical Specialist & Consultant
Ontario,Canada.
Email-pgoswami@sympatico.ca,
 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of solomon
Sent: Saturday, December 17, 2011 2:47 AM
To: materials-welding@googlegroups.com
Subject: [MW:13222] Impact test fail with A333 Gr6

Dear everyone
I do PQR with following data
1. pipe SA 333 Gr 6 (12" SCH. 160) and Flange SA 350 LF2
2. Joint design is single V
3. Process GTAW+SAW
4. Preheat 80C Min. with burner torch
5. With out backing gas for root pass
6. Use ER 80-S-Ni1 (BOHLER) two layer with total deposited about 5mm and 

The result of tensile, bend, marcro look very good.
Before impact test I already RT, UT, and MT to confirm that no defect
The impact test (joules) done at -46C, on the location as follow and the result as shown
FL,Root(Flange)            112,86,89
FL+2,Root(Flange)         26,61,107
FL,Root(Pipe)                25,130,12  
FL+2,Root(pipe)             24,14,19
FL,Middle(flange)            131,108,132
FL+2,Middle(flange)         194,154,200
FL,Middle(pipe)              38,56,125
FL+2,Middle(pipe)           80,124,112
WM,Root                        42,80,79
WM,Middle                     24,106,92 
 
The acceptance criteria is average 20 and Min. 16
From the result above I have to retest again with
FL,Root(pipe)                 37,19,20
FL+2,Root(pipe)             14,12,25

So I need some help from you guides to analyze the cause of this result. In my opinion I think it may come from one of below reason
1. the preheat temperature too low due to the thickness of base mat about 34 mm so the heat dissipate very quick for GTAW. 
2. skill of welder may be not familiar with this filler (add Ni)  so the fusion to base material not deep enough even the NDE result not shown any defect
Due to I don have remaining mat. enough to do it many time I need some advice from yours
Thanks you in advance for your kind support
Bye
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...