In actual practise there is no issue for coating prior to hydrotest ; but all weld joints should be left exposed ; which should be coated only after hydrotest
-- On 7 October 2011 13:36, jesti fer <jesti_fer@yahoo.com> wrote:
--Dear Experts,Any body can help me??????in our project some CS (P#1) piping spool whant do the "THRU-KOTE" sleeves as per drawing, but we are planing to do this coating after hydro test but our construction team planing to do before hydro, if any body know anything about THRU-KOTE plse give advise to me and the coating can do before hydro static testKindly help me as soon as possible
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: