Dear all
As per Shell  MESC SPE 76/212,we have to carry out  IGC Pr E test  for ASTM A182 F53 flanges.As per IGC test Pr E,Sensitisation to be carried out around 675deg C for 1 hour.Whether sensitisation required for DSS flanges.Kindly throw some light on above issue.



With Warm regards,

G.Padmanabhan

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...