Monday, July 26, 2010
[MW:6127] inconell 625 weld cladding on AISI 4130 material
Dear Team members,
It is required to qualify Nickell Alloy 625 overlay (10% FE max) on AISI 4130 at 1/8" minimum finished overlay deposited thickness.
Have anybody ever been faced with this before to share the experiance?
thanks.
Martin.
Hotmail: Trusted email with Microsoft's powerful SPAM protection. Sign up now.
Hotmail: Powerful Free email with security by Microsoft. Get it now.
Subscribe to:
Post Comments (Atom)
Re: [MW:35289] Welding consumable for S355J2WP material
S355 J2 WP is a weathering structural steel It has better atmospheric corrosion resistance. Use E 8018 - W1/W2 Electrodes This is regular...
-
Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? ...
-
Definition of buttering from ASME Section IX, QW/QB-492 Definitions: Buttering: the addition of material, by welding, on one or bot...
-
Section I. PRINT READING 3-1. GENERAL a. Drawings . Drawing or sketching is a universal language used to convey all necessary information to...