Sent from my Nokia phone
-----Original Message-----
From: veloumany siva
Sent: 02/06/2010 8:41:33 pm
Subject: [MW:5355] ER316 & E316-16 FOR CRYOGENIC SERVICE
Dear all,
one of our Client specification says"Qualification on Material Gr.316 also qualifies for Gr.316L but not Vice versa"
I want to esatblish WPS for Stainless steel Material Gr.316 (cryogrnic service) as per B31.3
My query is
whether ER316 for GTAW Process and E316-16 for SMAW will meet the Impact requirement?
Regards,
S.Veloumany
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.